Collecting logs from Yokogawa FAST/TOOLS and sending them to ArcSight Logger could be complex due to this unique combination of log sources and the SIEM solution. In this post, we will look at how you can forward log data from Yokogawa FAST/TOOLS to ArcSight Logger using NXLog.
Yokogawa FAST/TOOLS
FAST/TOOLS is Yokogawa’s SCADA software platform. Its client-server architecture comprises three main functional components: a SCADA server, a Web HMI client, and a Web HMI server. The SCADA server is responsible for collecting, processing, and managing the logs it receives from the Web HMI clients. The Web HMI server displays events and other operational data from Web HMI clients while also serving as the human-machine interface for displaying the logs that the SCADA server has processed.
FAST/TOOLS comprises several function-specific modules that include OPC server and client functionality and a history scheduler. The FAST/TOOLS software platform integrates with cloud computing and virtualization infrastructures. It is widely deployed in the oil and gas industry and large manufacturing plants worldwide.
Collecting Yokogawa FAST/TOOLS logs
FAST/TOOLS produces a wide variety of logs about its operations.
These logs are available in flat files and stored in the C:\Users\Public\Yokogawa\tls\log\
system directory.
There is no room for error or trade-offs because Yokogawa FAST/TOOLS monitors and controls the type of operations Its steady, uninterrupted operation is essential to maintaining plant safety. However, due to excessive log noise, valuable information can sometimes remain hidden in the logs it collects. Another challenge is the lack of consistent log formats. The ability to parse data from various log formats is an absolute necessity.
NXLog Enterprise Edition is a lightweight, modular log collection tool capable of tackling the most challenging cases log collection may pose. Its rich features allow it to read almost any log format and parse fields to produce structured data for further processing. It is the perfect tool for monitoring and collecting FAST/TOOLS logs.
- RDBMS data collection
-
FAST/TOOLS provides an ODBC (open database connectivity) interface that collects data from the FAST/TOOLS data set services layer and sends it directly to an external ODBC compliant database. With FAST/TOOLS, you can view table components and perform faster queries, obtaining much quicker insight into your plant operations. FAST/TOOLS includes an embedded relational database management system (RDBMS) that allows you to execute more complex queries and cross-reference FAST/TOOLS data with your own RDBMS environment.
- Collecting FAST/TOOLS logs from file
-
FAST/TOOLS' file-based logs include start logs, diagnostics logs, system monitor logs, and systems error logs. The processes that detect system errors send messages to the FAST/TOOLS unsolicited message handler (UMH), which manages all the necessary information present in these logs. This information includes the name of the process that detected the error, a timestamp, and an error code. You can view these application error logs in the
messages.umh
file of the FAST/TOOLS data directory. NXLog is capable of parsing these complex logs by using regular expressions. - FAST/TOOLS passive network monitoring
-
FAST/TOOLS supports open platform communications (OPC) functionality and includes an embedded OPC Unified Architecture (UA) environment. It also supports classic OPC for distributed communication (DCOM) links across your network. NXLog can passively monitor your network traffic and generate logs for most network protocols.
NXLog’s data normalization and log aggregation capabilities can extend the functionality of Yokogawa FAST/TOOLS. Because NXLog can collect logs from literally any file in any format, it is ideally suited for integrating with FAST/TOOLS' wide variety of log types and file formats.
For more information on integrating NXLog with this SCADA software environment, visit our detailed Yokogawa FAST/TOOLS integration guide.
The log sources mentioned above and NXLog’s features play an important role in normalizing logs to meet ArcSight Logger’s requirements.
Sending logs to Micro Focus ArcSight Logger
Micro Focus ArcSight Logger is a log management solution that provides secure storage, efficient search, reporting, and log data analysis. NXLog integrates with ArcSight Logger by sending logs in Common Event Format (CEF) over UDP or TCP. NXLog also supports receiving logs from an ArcSight Logger Forwarder.
- CEF TCP Receiver
-
A CEF TCP Receiver must be created from the Logger user interface for ArcSight Logger to receive logs over UDP or TCP. NXLog supports log collection from various sources and can transform the data to CEF using the xm_cef extension.
- TCP Forwarder
-
An ArcSight Logger forwarder can be configured to forward events to a remote server over UDP or TCP. A TCP Forwarder needs to be configured to forward events to NXLog. It sends data in the same format that ArcSight Logger ingests.
For more information on configuring NXLog and sending logs to ArcSight Logger, please visit the ArcSight Logger integration section in the NXLog User Guide.