Collecting logs from AVEVA System Platform and sending them to LogPoint could be complex because of the unique combination of the log source and the desired destination. This post will show you how to forward log data from AVEVA System Platform to LogPoint by incorporating the NXLog log collection tool.
AVEVA System Platform
AVEVA System Platform is a modular and scalable industrial software platform for software solutions focused on industrial automation and engineering personnel, including SCADA, HMI, IIoT, and Manufacturing Execution Systems (MES). AVEVA System Platform supports both the supervisory control layer and the manufacturing execution system (MES) layer, presenting them as a single information source.
Collecting AVEVA System Platform logs
AVEVA System Platform produces a wide variety of logs concerning its operations. Some of those logs are available through Windows Event Log and network monitoring, but most exist as flat files.
AVEVA System Platform controls systems of significant financial and security importance. In mission-critical settings, the timely collection and processing of AVEVA System Platform logs is crucial to the reliability and security of the systems it controls. Even a brief interruption of normal operations could result in catastrophic consequences. However, the sheer diversity of log formats and data structures, and the noise that some of these logs contain, pose severe challenges to most logging software.
NXLog Enterprise Edition is a lightweight, modular log collection tool capable of tackling the most challenging cases log collection may pose. Its rich features allow it to read almost any log format and parse fields to produce structured data for further processing. It is the perfect tool for monitoring and collecting AVEVA System Platform logs.
- Collecting AVEVA System Platform logs from Windows Event Log
-
Many applications send their logs directly to Windows Event Log, the preferred logging facility on the Windows platform. AVEVA System Platform sends its diagnostic and security-related events, such as user authentication, the state of system components, record modifications, and information about various other services to Windows Event Log. Logs can be read and collected using an Event ID related to AVEVA System Platform or by a given source name.
- Collecting AVEVA System Platform logs from file
-
File-based AVEVA System Platform logs include logs from:
-
ArchestrA system
-
ArchestrA Logger and Log Viewer
-
Historian Search
-
Historian Configuration Exporter error
-
InTouch Access Anywhere
-
License Server
-
- Collecting AVEVA System Platform logs from database tables
-
AVEVA System Platform reads information from database tables and provides insights into internal components and process-related data such as tag data, process alarms, and process events. Logs are collected from the following databases:
-
System Monitor
-
Runtime
-
Holding
-
Alarm
-
Records from history blocks
-
- AVEVA System Platform Network Monitoring
-
AVEVA System Platform supports open platform communications (OPC) functionality, SuiteLink, DDE/FastDDE, and ArchestrA Message Exchange. NXLog can passively monitor network traffic and generate logs for most network protocols.
The easiest way to collect and normalize AVEVA System Platform logs is by deploying NXLog. With its unique capabilities, logs can be collected from literally any file in any format. Given the wide variation in format and structure of such log files, its versatility is ideal for these systems.
For more information on integrating NXLog with AVEVA System Platform, see the AVEVA System Platform integration guide.
The sources mentioned above and NXLog’s features play an important role in normalizing logs accepted by LogPoint.
Sending logs to LogPoint
LogPoint is a SIEM solution that monitors and analyzes log data. It offers real-time threat detection and response and visualizes aggregate event data collected from different sources.
- Log sources
-
For LogPoint to accept logs from a source, it must first be added to its device repository. NXLog can integrate directly with LogPoint by sending log data to it in syslog format over TCP or UDP. NXLog also supports receiving logs from the LogPoint Raw Syslog Forwarder (RSF).
- Forwarding logs
-
LogPoint provides the LPA_Windows and JSONCompiledNormalizer compiled normalizers to parse events from Windows Event Log, requiring data to be in JSON format. NXLog can forward events compatible with the format required by these normalizers using the JSON (xm_json) extension module.
NXLog can forward logs to LogPoint over a secure channel using the om_ssl output module. By default, LogPoint’s Syslog Collectors listen for secure connections on port 6514 and use certificates located in the following path:
/opt/immune/etc/remote_connection/certificates/